EFRP-3400S

750W,AC/DC热插拔服务器电源,ATX输出,3U冗余电源

产品品牌:Etasis
原 产 地:台湾

altFeatures :
 
Universal Power Input
Active Power Factor Correction
Current Sharing on +5V, +3.3V and +12V
Remote DC Sense on +5V, +3.3V and +12V
Front Panel LED to Indicate Power Status
Power Fault Alarm Signals
Over Voltage Protection
Over Current Protection
Short Circuit Protection
MTBF >100,000 Hours

 

altGeneral Specifications :
 
Input Range: 100 to 240 VAC, ±10%
Power Factor: >0.95 minimum
Efficiency: 65% minimum, at full load
Hold up Time: 17mS minimum, at 80% load
PSON (Remote ON/OFF): TTL compatible
Power Good: 100 to 500 ms, TTL compatible
Cooling Fan: 38x38x28 mm (SANYO DENKI)
Operating Temperature: 0 to 50 ºC
Operating Humidity: 20 to 90 %

 

altRegulation, Ripple & Noise:
 
Output
+3.3V
+5V
+12V1
+12V2
+12V3
+12V4
-5V
-12V
+5Vsb
Load Regulation
+5/-4%
+5/-3%
+5/-4%
+5/-4%
+5/-4%
+5/-4%
 
+9/-5%
+5/-3%
Cross Regulation
+5/-4%
+5/-3%
+5/-4%
+5/-4%
+5/-4%
+5/-4%
 
+9/-5%
+5/-3%
Line Regulation
± 1%
± 1%
± 1%
± 1%
± 1%
± 1%
 
± 1%
± 1%
Ripple & Noise
50mV
50mV
120mV
120mV
120mV
120mV
 
50mV
50mV

 

altInput and Output Ratings:
 
Input
Output
Voltage
Frequency
Current
Watt
Load
+3.3V
+5V
+12V1
+12V2
+12V3
+12V4
-5V
-12V
+5Vsb
100~240VAC
47-63 Hz
7~14A
750W
Max. Load
30A
30A
16A
16A
16A
16A
 
0.5A
3A
Min. Load
1A
1.5A
0.8A
0.8A
0.8A
0.8A
 
0A
0.1A

altNOTE:

  1. The +5 & +3.3 Volt total output shall not exceed 170 W.
  2. The +5, +3.3 & +12Volt total output shall not exceed 740W.
  3. Maximum continues total DC output power shout not exceed 750W.
  4. Maximum combined current for the 12 V outputs shall be 60A.

 

altAgency Requirements :
 
Harmonic: Meet EN61000-3-2
EMI/RFI: CE, FCC class B
Safety: UL, cUL, TUV, CB, CCC